The new device family for professional use in doctor’s practice, clinics or
sport’s medicine
Up to 120 samples per hour
Chip-Sensor for user-friendly and safe
handling
Easiest
sample handling
Quality control under the regulations of
German "RiliBäk”
Low operating costs by minimal reagent
consumption
Compact design
Barcode reader optional
The BIOSEN C_line is especially developed for professional
use in doctor's practice, clinic or special issues, like for example sports
medicine.
The use of special chip-sensor technology therefore guarantee fast
measurements, a maximum amount of precision and user-friendly prompt. More
than 10 years of experience influenced the development of this appliances.
The idea was to design instruments which meet the special requirements of
different medical issues. We hit this target by offering special assemblies and
the customer´s possibility to add, subtract or change parts of the system by
himself.
A state of the art graphical touch screen assures an easy display guided
work. The instruments are fitted with an extensive memory and the possibility of
adjustment of lots of system parameters. Printer and interfaces complete the
system.
The 4 basic
configurations:
BIOSEN C_line, Package
GP
BIOSEN C_line, Package
Clinic
BIOSEN C_line, Package
GP+
BIOSEN C_line, Package
Sport
Overview of functional
details:
Package GP
Package GP+
Package Clinic
Package Sport
Quality control
Cost-cutting consumption
Memory for 500 results
Graphical Touchscreen
Automatic sample
recognition
Barcode reader
mobile use possible (with optional
DC/AC-converter)
1. Parameter
Glucose/Lactate
2. Parameter
Glucose/Lactate
STAT sample
*
**
*
Standard- / Control
positions
2 / 2 *
2 / 2 *
2 / 2 **
2 / 2 *
Number of samples
1
5
20
15
Throughput per hour
ca. 25
ca. 60
ca. 120
ca. 100
Calibration modes
3
3
3
3
standard
*
integrated
optional
**
separate
not availlable
Technical Data
Measuring principle
enzymatic, amperometric
Electrode
Chip-Sensor(s)
Range Glucose
0.5-50 mmol/l (9-900 mg/dl)
Range Lactate
0.5-40 mmol/l (5-360 mg/dl)
Un-precision
Cv </= 1.5%@12 mmol
Stability / Drift
</= 3 % at 10 samples, referring to 12 mmol/l
Lifetime of Sensors Glucose
60 days or approx. 7500 tests; typical: 60 days
Lifetime of Sensors Lactate
40 days or approx. 6000 tests
Sample material
blood, plasma or serum
Sample volume
20 µl (10 µl)
Reaction container
2,0 ml (1,5 ml)
Calibration modes
By starting, periodic, TimeAccount
Display / Keyboard
Graphical touch screen ( 320 x 240 dots)
Memory
500 results with position, date, time
Languages
German, English, Spanish, French, Portuguese, Russian, Polish,
Czech Other languages on request